ASTM Corrugated Switchboard Mats

Image

Description

Non-conductive mats are designed for electrical protection in industrial and high-voltage environments. They are ideal for substations, switchgear, control panels, and generator areas.

Features

  • Corrugated surface for safety and traction
  • Non-conductive compound
  • Certification printed on back

Materials

  • High-performance insulating rubber
  • Tested to ASTM D178 / ANSI J6.7 standards

Sizes & Configurations

  • Class 1: 3/16”, Dielectric 20,000 VAC, Proof 10,000 VAC, Max 7,500 VAC
  • Class 2: 1/4”, Dielectric 30,000 VAC, Proof 20,000 VAC, Max 17,000 VAC
  • Class 3: 3/8”, Dielectric 40,000 VAC, Proof 30,000 VAC, Max 26,500 VAC
  • Class 4: 1/2”, Dielectric 50,000 VAC, Proof 40,000 VAC, Max 36,500 VAC
  • Roll lengths: Classes 1–3: 25-yd; Class 4: 10-yd
  • Diamond surface available for Class 2

Applications

  • Substations, switchgear, control panels, engine rooms, generators

Benefits

  • Proven insulation
  • Reliable industry performance
  • Multiple gauge options

Type II CLASS 1 - 3/16” Thick Switchboard - Corrugated

See Product Specs

Image
  • DIELECTRIC TEST VOLTAGE 20,000 VAC
  • Proof Tested over entire surface at 10,000 VAC
  • Recommended Maximum Use Voltage 7,500 VAC
Stock # Size Weight/Ln.Ft.
SB336 3’ × 75’ 3.9 lbs.
Color: Black. Sold in cut lengths and full rolls.

Type II CLASS 2 - 1/4” Thick Switchboard - Corrugated Pattern

See Product Specs

Image
  • DIELECTRIC TEST VOLTAGE 30,000 VAC
  • Proof Tested over entire surface at 20,000 VAC
  • Recomended Maximum Use Voltage 17,000 VAC
Stock # Size Weight/Lin.Ft.
SB424 2’ × 75’ 3.5 lbs.
SB436 3’ × 75’ 5.2 lbs.
SB448 4’ × 75’ 6.8 lbs.
Color: Black. 3’ Diamond also in black/yellow. Sold in cut lengths and full rolls

CLASS 4 - 1/2” Thick Switchboard - Corrugated

See Product Specs

Image
  • DIELECTRIC TEST VOLTAGE 50,000 VAC
  • PROOF TESTED OVER ENTIRE SURFACE AT 40,000 VAC
  • RECOMMENDED MAXIMUM USE VOLTAGE 36,000 VAC
Stock # Size Weight/Lin.Ft.
SB636 3’ × 30’ × 1/2” 10.7 lbs.
Color: Black. Sold in cut lengths and full rolls. Optional Bevel.

Type II CLASS 3 - 3/8” Thick Switchboard - Corrugated

See Product Specs

Image
  • DIELECTRIC TEST VOLTAGE 40,000 VAC
  • Proof Tested over entire surface at 30,000 VAC
  • Recommended Maximum Use Voltage 26,500 VAC
Stock # Size Weight/Lin.Ft.
SB536 3’ × 75’ 7.7 lbs.
Color: Black. Sold in cut lengths and full rolls.

When personnel safety from electrocution hazard is a concern,
specify Rhino Switchboard matting.